Please enable JavaScript in your browser to complete this form.Please enable JavaScript in your browser to complete this form.Customer detailRef. No. *Customer Name *Attention to *Email *Tel No. *ProductSelect Product *T5500 Pressure GaugeB-Series Switches – Pressure, Differential Pressure & HydraulicT5500 Pressure GaugeVolume123ProductDial Size *100 - 100 mm160 - 160 mmModel *T5500 - Open front stainless steel pressure gaugeT6500 - Solid front stainless steel pressure gaugeWetted Parts Material *S - Stainless steel 316L (1.4404) tube and socketP - Monel tube and socketCase Filling *D - Dry caseL - Liquid fillied caseProcess Connection *02 - 1⁄4” NPT male03 - 3/8” NPT male04 - 1⁄2’’ NPT male09 - 9/16-18 UNF-2B Aminco13 - G 1⁄4 B male14 - G 3/8 B male15 - G 1⁄2 male16 - M20x1,5 male25 - 1⁄4’’ NPT femaleEJ - 7/16-20 UNF-3A 37° FlareKJ - PF 1⁄4 B parallel pipe male (JIS B 0202)KN - PF 1⁄2 B parallel pipe male (JIS B 0202)KP - PF 3/8 B parallel pipe male (JIS B 0202)KQ - R 1⁄2 DIN EN 10226-1 (1⁄2’’ BSPT / JIS B 0203)KR - R 3/8” DIN EN 10226-1 (3/8”’’ BSPT / JIS B 0203)RF - 9/16-18 UNF for 3⁄8” O.D. tubingConnection Location *B - Back (not available for model T6500)L - LowerRANGE *Engineering Unit *Additional OptionsAccuracyAJ - Special accuracy 0,5 % grade 2A according to ASME B40.100 (Not for ranges < 1 bar (dry) or < 4 bar (liquid filled))Agency ApprovalATEX - ATEX approval (see page 1) (only available with laminated safety glass)EAC - Custom declaration according Eurasian Conformity (Not in combination with option ATEX)Case MaterialYW - Case and ring material stainless steel 316LCase And RingBQ - Wall mounting bracketFF - Front flange on bayonet ring (Not for dial size 160 mm)FW - Wall mounting flangeFX - Front flange tack welded to caseUF - U-clamp for panel mounting (Not for model T6500)ConnectionTU - Throttle plugWP - No throttle plug in dry or liquid filled casesLiquid FillingGQ - White oilGR - Glycerine 99,5%GV - SiliconeGX - HalocarbonQC - Low temperature silicone for ambient temperature up to -70°C, includes Flourosilicone sealing (For 100 mm T6500 only)LJ - Field fillableDial OptoinsAB - Absolute pressureCS - Combination range / Dual scaleDN - Dial calibrated at angle other than vertical (Information is required by the customer)E6 - Dial pin in 6 o ́clock positionON - Without Ashcroft logo, neutralPR - Receiver gauge (Information is required by the customer)SS - Special Scale (Information is required by the customer)6Y - Skydrol useMovementLL - PLUS!TM Performance (Not available with Halocarbon filling)NZ - PLUS!TM Performance silicone free (Not for execution L (liquid filled))OS - Overload range stopVS - Underload range stop up to -1 barSM - Stainless steel 316L (1.4404) movementPointerMP - Adjustable micrometer pointerWindow *PD - Polycarbonate windowSG - Laminated safety glass (Standard with model T6500)EP - Maximum pointer and polycarbonate windowEQ - Minimum Pointer and polycarbonate windowSH - Red set hand stationary and polycarbonate windowAssemblyMO - Instrument assembled to accessoryMO1 - Instrument assembled to diaphragm sealCleaning6B - Cleaned for gaseous Oxygen or other strong oxidizing agents (Not for T5500 (open front) acc. to EN 837-1 and information is required by the customer)6W - Cleaned “free of oil and grease” (no Oxygen service)MF - Free from Mercury contaminationYF - Cleaned silicone free productMarking And TaggingDA - Dial marking printed on dial (Information is required by the customer)NH - Stainless steel tagging wired (Information is required by the customer)NH1 - Extra lage stainless steel tagging, wired (120 x 30 x 1 mm) (Information is required by the customer)Material CertificateCD2 - Certificate according to EN 10204 2.2C3 - Certificate according to EN 10204 3.1CD5 - Certificate according to NACE for Oilfields MR0175 / ISO 15156-2015 and for Refineries MR0103 / ISO 17945-2015MQ - Positive material certificate (PMI)Test CertificateC4 - CD-4 calibration certificateC43 - CD-4 calibration certificateCD10 - Calibration certificate 10 pointsHY - Hydrostatic pressure testML - Mass spectrometer leak testFile Upload Click or drag a file to this area to upload. Quantity *T5500 Pressure Gauge #2Product #2 *Dial Size #2 *100 - 100 mm160 - 160 mmModel #2 *T5500 - Open front stainless steel pressure gaugeT6500 - Solid front stainless steel pressure gaugeWetted Parts Material #2 *S - Stainless steel 316L (1.4404) tube and socketP - Monel tube and socketCase Filling #2 *D - Dry caseL - Liquid fillied caseProcess Connection #2 *02 - 1⁄4” NPT male03 - 3/8” NPT male04 - 1⁄2’’ NPT male09 - 9/16-18 UNF-2B Aminco13 - G 1⁄4 B male14 - G 3/8 B male15 - G 1⁄2 male16 - M20x1,5 male25 - 1⁄4’’ NPT femaleEJ - 7/16-20 UNF-3A 37° FlareKJ - PF 1⁄4 B parallel pipe male (JIS B 0202)KN - PF 1⁄2 B parallel pipe male (JIS B 0202)KP - PF 3/8 B parallel pipe male (JIS B 0202)KQ - R 1⁄2 DIN EN 10226-1 (1⁄2’’ BSPT / JIS B 0203)KR - R 3/8” DIN EN 10226-1 (3/8”’’ BSPT / JIS B 0203)RF - 9/16-18 UNF for 3⁄8” O.D. tubingConnection Location #2 *B - Back (not available for model T6500)L - LowerRANGE #2 *Engineering Unit #2 *Additional OptionsAccuracy #2AJ - Special accuracy 0,5 % grade 2A according to ASME B40.100 (Not for ranges < 1 bar (dry) or < 4 bar (liquid filled))Agency Approval #2ATEX - ATEX approval (see page 1) (only available with laminated safety glass)EAC - Custom declaration according Eurasian Conformity (Not in combination with option ATEX)Case Material #2YW - Case and ring material stainless steel 316LCase And Ring #2BQ - Wall mounting bracketFF - Front flange on bayonet ring (Not for dial size 160 mm)FW - Wall mounting flangeFX - Front flange tack welded to caseUF - U-clamp for panel mounting (Not for model T6500)Connection #2TU - Throttle plugWP - No throttle plug in dry or liquid filled casesLiquid Filling #2GQ - White oilGR - Glycerine 99,5%GV - SiliconeGX - HalocarbonQC - Low temperature silicone for ambient temperature up to -70°C, includes Flourosilicone sealing (For 100 mm T6500 only)LJ - Field fillableDial Optoins #2AB - Absolute pressureCS - Combination range / Dual scaleDN - Dial calibrated at angle other than vertical (Information is required by the customer)E6 - Dial pin in 6 o ́clock positionON - Without Ashcroft logo, neutralPR - Receiver gauge (Information is required by the customer)SS - Special Scale (Information is required by the customer)6Y - Skydrol useMovement #2LL - PLUS!TM Performance (Not available with Halocarbon filling)NZ - PLUS!TM Performance silicone free (Not for execution L (liquid filled))OS - Overload range stopVS - Underload range stop up to -1 barSM - Stainless steel 316L (1.4404) movementPointer #2MP - Adjustable micrometer pointerWindow #2 *PD - Polycarbonate windowSG - Laminated safety glass (Standard with model T6500)EP - Maximum pointer and polycarbonate windowEQ - Minimum Pointer and polycarbonate windowSH - Red set hand stationary and polycarbonate windowAssembly #2MO - Instrument assembled to accessoryMO1 - Instrument assembled to diaphragm sealCleaning #26B - Cleaned for gaseous Oxygen or other strong oxidizing agents (Not for T5500 (open front) acc. to EN 837-1 and information is required by the customer)6W - Cleaned “free of oil and grease” (no Oxygen service)MF - Free from Mercury contaminationYF - Cleaned silicone free productMarking And Tagging #2DA - Dial marking printed on dial (Information is required by the customer)NH - Stainless steel tagging wired (Information is required by the customer)NH1 - Extra lage stainless steel tagging, wired (120 x 30 x 1 mm) (Information is required by the customer)Material Certificate #2CD2 - Certificate according to EN 10204 2.2C3 - Certificate according to EN 10204 3.1CD5 - Certificate according to NACE for Oilfields MR0175 / ISO 15156-2015 and for Refineries MR0103 / ISO 17945-2015MQ - Positive material certificate (PMI)Test Certificate #2C4 - CD-4 calibration certificateC43 - CD-4 calibration certificateCD10 - Calibration certificate 10 pointsHY - Hydrostatic pressure testML - Mass spectrometer leak testFile Upload #2 Click or drag a file to this area to upload. Quantity #2 *T5500 Pressure Gauge #3Product #3 *Dial Size #3 *100 - 100 mm160 - 160 mmModel #3 *T5500 - Open front stainless steel pressure gaugeT6500 - Solid front stainless steel pressure gaugeWetted Parts Material #3 *S - Stainless steel 316L (1.4404) tube and socketP - Monel tube and socketCase Filling #3 *D - Dry caseL - Liquid fillied caseTest Certificate #3C4 - CD-4 calibration certificateC43 - CD-4 calibration certificateCD10 - Calibration certificate 10 pointsHY - Hydrostatic pressure testML - Mass spectrometer leak testFile Upload #3 Click or drag a file to this area to upload. Quantity #3 *B-Series Switches – Pressure, Differential Pressure & HydraulicVolume123ProductEnclosure *B4 - Pressure switch, Type 400, watertight enclosure meets NEMA 3, 4, 4X, 13 and IP66 requirements.B7 - Pressure switch, Type 700, explosion-proof enclosure meets Div. 1 & 2, NEMA 7, 9 and IP66 requirements. Standard housing epoxy coated aluminum. Use variation code XYW for 316SS housing.D4 - Differential pressure switch, Type 400, water-tight enclosure meets NEMA 3, 4, 4X, 13 and IP66 requirements.D7 - Differential pressure switch, Type 700, explosion- proof enclosure meets Div. 1 & 2, NEMA 7, 9 and IP66 requirements. Standard housing epoxy coated aluminum. Use variation code XYW for 316SS housing.Switch Element Selection - UL/CSA Listed SPDT20 - Narrow deadband ac, 15A - 125/250 Vac. Estimated dc rating, 0.4A, 120 Vdc (not UL listed).21 - Ammonia service, 5A - 125/250 Vac22 - Hermetically sealed switch, narrow deadband, 5A - 125/250 Vac. Estimated dc. rating, 2.5A, 28 Vdc (not UL listed).23 - Heavy duty ac, 22A - 125/250 Vac24 - General purpose, 15A - 125/250/480 Vac, 1⁄2A - 125 Vdc, 1⁄4A - 250 Vdc; 6A, 30 Vdc. (Standard switch)25 - Heavy duty dc, 10A - 125 Vac or dc,1⁄8 HP - 125 Vac or dc. Not available with psid ranges.26 - Sealed environment proof, 15A - 125/250 Vac. Estimated dc rating, 0.4A, 120 Vdc (not UL listed).27 - High temperature 300 °F, 15A - 125/250 Vac28 - Manual reset trip on, increasing 15A - 125/250 Vac. Not available with type 700 enclosure.29 - Manual reset trip on decreasing, 15A - 125/250 Vac. Not available with type 700 enclosure.31 - Low level (gold) contacts, 1A - 125 Vac32 - Hermetically sealed switch, general purpose, 11A - 125/250 Vac, 5A - 30 Vdc42 - Hermetically sealed switch, gold contacts, 1A - 125 Vac50 - Variable deadband, 15A - 125/250 VacSwitch Element Selection - UL/CSA Listed Dual (2 SPDT)61 - Dual narrow deadband, 15A - 125/250 Vac. Estimated dc rating, 0.4A, 120 Vdc (not UL listed).62 - Dual sealed environment proof, 15A - 125/250 Vac. Estimated dc rating, 0.4A, 120 Vdc (not UL listed).63 - Dual high temp. 300 °F, 15A - 125/250 Vac64 - Dual general purpose, 15A - 125/250/480 Vac, 1⁄2A- 125 Vdc, 1⁄4A - 250 Vdc65 - Dual ammonia service, 5A - 125/250 Vac67 - Dual hermetically sealed switch, narrow deadband, 5A - 125/250 Vac. Wires cannot be terminated inside B400 switch enclosure. Estimated dc. rating, 2.5A, 28 Vdc (not UL listed).68 - Dual hermetically sealed switch, general purpose, 11A - 125/250 Vac 5A, 30 Vdc. Wires cannot be terminated inside B400 switch enclosure.70 - Dual low level gold contacts, 1A - 125 Vac71 - Dual hermetically sealed switch, gold contacts, 1A - 125 Vac. Wires cannot be terminated inside B400 switch enclosure.Actuator Seal & Process Temp.B - Buna-N / 0 to 150V - VitonTM / 20 to 300T - TeflonTM / 0 to 150S - 316L / 0 to 300P - Monel® / 0 to 300OPTIONAL FEATURES AND ACCESSORIESXBP - Wall Mounting Bracket in. H2OXCH - Chained CoverXC8 - CSA ApprovalXCN - ATEX Directive 94/9/EC/IECEx RatingXC4 - Traceable Calibration CertificateXD2 - Dual Seal Rating (700 Series only)XFM - FM Approval – Single Element FM Approval – Dual ElementXFP - Fungus ProofingXFS - Factory Adjusted SetpointXG3 - Belleville ActuatorXG5 - UL Limit Control to 150 in. H2OXG6 - UL Limit Control to 600 psiXG7 - Secondary Chamber with VentXG8 - Steam Limit Control to 300 psiXG9 - Fire Safe Welded ActuatorXHS - High Static Differential PressureXHX - 160 psi (proof) d/p only 100 psi (proof) pressure only (in. H2O)XJK - Left Conduit ConnectionXJL - 3⁄4 ̋ to 1⁄2 ̋ Reducing BushingXJM - Metric Electrical Conduit Conn. M20 x 1.5XK3 - Terminal Block (700 Series only)XLE - 6 foot Leads on the Micro SwitchXNH - Tagging Stainless SteelXNN - Paper TagXPK - Pilot Light(s) Top MountedXPM - 3⁄4 ̋ Sealed Conduit Connection w/16 ̋ Lead WiresXTA - 316 Stainless Steel Pressure Connection for in. H2O RangeXTM - 2 ̋ Pipe Mounting BracketXUD - 316 Stainless Steel Pressure Conn.X06 - Pressure Connection: 1⁄2 NPT Male, 1⁄4 NPT Female 316 Stainless Steel (Combination)X07 - 1⁄2 NPTF Press. Conn., 316 SSX6B - Cleaned for Oxygen ServiceX9F - Inches of Water Housing for Outdoor UseXYW - 316SS HousingXMD - Metric Range on LabelXRN - Range ScaleRANGE *File Upload Click or drag a file to this area to upload. Quantity *B-Series Switches – Pressure, Differential Pressure & Hydraulic #2Product #2Enclosure #2 *B4 - Pressure switch, Type 400, watertight enclosure meets NEMA 3, 4, 4X, 13 and IP66 requirements.B7 - Pressure switch, Type 700, explosion-proof enclosure meets Div. 1 & 2, NEMA 7, 9 and IP66 requirements. Standard housing epoxy coated aluminum. Use variation code XYW for 316SS housing.D4 - Differential pressure switch, Type 400, water-tight enclosure meets NEMA 3, 4, 4X, 13 and IP66 requirements.D7 - Differential pressure switch, Type 700, explosion- proof enclosure meets Div. 1 & 2, NEMA 7, 9 and IP66 requirements. Standard housing epoxy coated aluminum. Use variation code XYW for 316SS housing.Switch Element Selection - UL/CSA Listed SPDT #220 - Narrow deadband ac, 15A - 125/250 Vac. Estimated dc rating, 0.4A, 120 Vdc (not UL listed).21 - Ammonia service, 5A - 125/250 Vac22 - Hermetically sealed switch, narrow deadband, 5A - 125/250 Vac. Estimated dc. rating, 2.5A, 28 Vdc (not UL listed).23 - Heavy duty ac, 22A - 125/250 Vac24 - General purpose, 15A - 125/250/480 Vac, 1⁄2A - 125 Vdc, 1⁄4A - 250 Vdc; 6A, 30 Vdc. (Standard switch)25 - Heavy duty dc, 10A - 125 Vac or dc,1⁄8 HP - 125 Vac or dc. Not available with psid ranges.26 - Sealed environment proof, 15A - 125/250 Vac. Estimated dc rating, 0.4A, 120 Vdc (not UL listed).27 - High temperature 300 °F, 15A - 125/250 Vac28 - Manual reset trip on, increasing 15A - 125/250 Vac. Not available with type 700 enclosure.29 - Manual reset trip on decreasing, 15A - 125/250 Vac. Not available with type 700 enclosure.31 - Low level (gold) contacts, 1A - 125 Vac32 - Hermetically sealed switch, general purpose, 11A - 125/250 Vac, 5A - 30 Vdc42 - Hermetically sealed switch, gold contacts, 1A - 125 Vac50 - Variable deadband, 15A - 125/250 VacSwitch Element Selection - UL/CSA Listed Dual (2 SPDT) #261 - Dual narrow deadband, 15A - 125/250 Vac. Estimated dc rating, 0.4A, 120 Vdc (not UL listed).62 - Dual sealed environment proof, 15A - 125/250 Vac. Estimated dc rating, 0.4A, 120 Vdc (not UL listed).63 - Dual high temp. 300 °F, 15A - 125/250 Vac64 - Dual general purpose, 15A - 125/250/480 Vac, 1⁄2A- 125 Vdc, 1⁄4A - 250 Vdc65 - Dual ammonia service, 5A - 125/250 Vac67 - Dual hermetically sealed switch, narrow deadband, 5A - 125/250 Vac. Wires cannot be terminated inside B400 switch enclosure. Estimated dc. rating, 2.5A, 28 Vdc (not UL listed).68 - Dual hermetically sealed switch, general purpose, 11A - 125/250 Vac 5A, 30 Vdc. Wires cannot be terminated inside B400 switch enclosure.70 - Dual low level gold contacts, 1A - 125 Vac71 - Dual hermetically sealed switch, gold contacts, 1A - 125 Vac. Wires cannot be terminated inside B400 switch enclosure.Actuator Seal & Process Temp. #2B - Buna-N / 0 to 150V - VitonTM / 20 to 300T - TeflonTM / 0 to 150S - 316L / 0 to 300P - Monel® / 0 to 300OPTIONAL FEATURES AND ACCESSORIES #2XBP - Wall Mounting Bracket in. H2OXCH - Chained CoverXC8 - CSA ApprovalXCN - ATEX Directive 94/9/EC/IECEx RatingXC4 - Traceable Calibration CertificateXD2 - Dual Seal Rating (700 Series only)XFM - FM Approval – Single Element FM Approval – Dual ElementXFP - Fungus ProofingXFS - Factory Adjusted SetpointXG3 - Belleville ActuatorXG5 - UL Limit Control to 150 in. H2OXG6 - UL Limit Control to 600 psiXG7 - Secondary Chamber with VentXG8 - Steam Limit Control to 300 psiXG9 - Fire Safe Welded ActuatorXHS - High Static Differential PressureXHX - 160 psi (proof) d/p only 100 psi (proof) pressure only (in. H2O)XJK - Left Conduit ConnectionXJL - 3⁄4 ̋ to 1⁄2 ̋ Reducing BushingXJM - Metric Electrical Conduit Conn. M20 x 1.5XK3 - Terminal Block (700 Series only)XLE - 6 foot Leads on the Micro SwitchXNH - Tagging Stainless SteelXNN - Paper TagXPK - Pilot Light(s) Top MountedXPM - 3⁄4 ̋ Sealed Conduit Connection w/16 ̋ Lead WiresXTA - 316 Stainless Steel Pressure Connection for in. H2O RangeXTM - 2 ̋ Pipe Mounting BracketXUD - 316 Stainless Steel Pressure Conn.X06 - Pressure Connection: 1⁄2 NPT Male, 1⁄4 NPT Female 316 Stainless Steel (Combination)X07 - 1⁄2 NPTF Press. Conn., 316 SSX6B - Cleaned for Oxygen ServiceX9F - Inches of Water Housing for Outdoor UseXYW - 316SS HousingXMD - Metric Range on LabelXRN - Range ScaleRANGE #2 *File Upload #2 Click or drag a file to this area to upload. Quantity #2 *B-Series Switches – Pressure, Differential Pressure & Hydraulic #3Product #3Enclosure #3 *B4 - Pressure switch, Type 400, watertight enclosure meets NEMA 3, 4, 4X, 13 and IP66 requirements.B7 - Pressure switch, Type 700, explosion-proof enclosure meets Div. 1 & 2, NEMA 7, 9 and IP66 requirements. Standard housing epoxy coated aluminum. Use variation code XYW for 316SS housing.D4 - Differential pressure switch, Type 400, water-tight enclosure meets NEMA 3, 4, 4X, 13 and IP66 requirements.D7 - Differential pressure switch, Type 700, explosion- proof enclosure meets Div. 1 & 2, NEMA 7, 9 and IP66 requirements. Standard housing epoxy coated aluminum. Use variation code XYW for 316SS housing.Switch Element Selection - UL/CSA Listed SPDT #320 - Narrow deadband ac, 15A - 125/250 Vac. Estimated dc rating, 0.4A, 120 Vdc (not UL listed).21 - Ammonia service, 5A - 125/250 Vac22 - Hermetically sealed switch, narrow deadband, 5A - 125/250 Vac. Estimated dc. rating, 2.5A, 28 Vdc (not UL listed).23 - Heavy duty ac, 22A - 125/250 Vac24 - General purpose, 15A - 125/250/480 Vac, 1⁄2A - 125 Vdc, 1⁄4A - 250 Vdc; 6A, 30 Vdc. (Standard switch)25 - Heavy duty dc, 10A - 125 Vac or dc,1⁄8 HP - 125 Vac or dc. Not available with psid ranges.26 - Sealed environment proof, 15A - 125/250 Vac. Estimated dc rating, 0.4A, 120 Vdc (not UL listed).27 - High temperature 300 °F, 15A - 125/250 Vac28 - Manual reset trip on, increasing 15A - 125/250 Vac. Not available with type 700 enclosure.29 - Manual reset trip on decreasing, 15A - 125/250 Vac. Not available with type 700 enclosure.31 - Low level (gold) contacts, 1A - 125 Vac32 - Hermetically sealed switch, general purpose, 11A - 125/250 Vac, 5A - 30 Vdc42 - Hermetically sealed switch, gold contacts, 1A - 125 Vac50 - Variable deadband, 15A - 125/250 VacSwitch Element Selection - UL/CSA Listed Dual (2 SPDT) #361 - Dual narrow deadband, 15A - 125/250 Vac. Estimated dc rating, 0.4A, 120 Vdc (not UL listed).62 - Dual sealed environment proof, 15A - 125/250 Vac. Estimated dc rating, 0.4A, 120 Vdc (not UL listed).63 - Dual high temp. 300 °F, 15A - 125/250 Vac64 - Dual general purpose, 15A - 125/250/480 Vac, 1⁄2A- 125 Vdc, 1⁄4A - 250 Vdc65 - Dual ammonia service, 5A - 125/250 Vac67 - Dual hermetically sealed switch, narrow deadband, 5A - 125/250 Vac. Wires cannot be terminated inside B400 switch enclosure. Estimated dc. rating, 2.5A, 28 Vdc (not UL listed).68 - Dual hermetically sealed switch, general purpose, 11A - 125/250 Vac 5A, 30 Vdc. Wires cannot be terminated inside B400 switch enclosure.70 - Dual low level gold contacts, 1A - 125 Vac71 - Dual hermetically sealed switch, gold contacts, 1A - 125 Vac. Wires cannot be terminated inside B400 switch enclosure.Actuator Seal & Process Temp. #3B - Buna-N / 0 to 150V - VitonTM / 20 to 300T - TeflonTM / 0 to 150S - 316L / 0 to 300P - Monel® / 0 to 300OPTIONAL FEATURES AND ACCESSORIES #3XBP - Wall Mounting Bracket in. H2OXCH - Chained CoverXC8 - CSA ApprovalXCN - ATEX Directive 94/9/EC/IECEx RatingXC4 - Traceable Calibration CertificateXD2 - Dual Seal Rating (700 Series only)XFM - FM Approval – Single Element FM Approval – Dual ElementXFP - Fungus ProofingXFS - Factory Adjusted SetpointXG3 - Belleville ActuatorXG5 - UL Limit Control to 150 in. H2OXG6 - UL Limit Control to 600 psiXG7 - Secondary Chamber with VentXG8 - Steam Limit Control to 300 psiXG9 - Fire Safe Welded ActuatorXHS - High Static Differential PressureXHX - 160 psi (proof) d/p only 100 psi (proof) pressure only (in. H2O)XJK - Left Conduit ConnectionXJL - 3⁄4 ̋ to 1⁄2 ̋ Reducing BushingXJM - Metric Electrical Conduit Conn. M20 x 1.5XK3 - Terminal Block (700 Series only)XLE - 6 foot Leads on the Micro SwitchXNH - Tagging Stainless SteelXNN - Paper TagXPK - Pilot Light(s) Top MountedXPM - 3⁄4 ̋ Sealed Conduit Connection w/16 ̋ Lead WiresXTA - 316 Stainless Steel Pressure Connection for in. H2O RangeXTM - 2 ̋ Pipe Mounting BracketXUD - 316 Stainless Steel Pressure Conn.X06 - Pressure Connection: 1⁄2 NPT Male, 1⁄4 NPT Female 316 Stainless Steel (Combination)X07 - 1⁄2 NPTF Press. Conn., 316 SSX6B - Cleaned for Oxygen ServiceX9F - Inches of Water Housing for Outdoor UseXYW - 316SS HousingXMD - Metric Range on LabelXRN - Range ScaleRANGE #3 *File Upload #3 Click or drag a file to this area to upload. Quantity #3 *Sales detailQT Date *Sales Name *ปริญญา บัณฑิตธรรมรวินท์รัชต์ เจียมใจงามโฆษิต โชติวิวัฒน์กิจมัลลิกา โรจน์คงทรัพย์มรกต คูสกุลนิรดา สุขหวานกีรติญา เนตรไธสงค์กนกกาญจน์ ธเนศชัยคุปต์NoteStatusNew OrderIn processFinishCancelSubmit Order Form Please enable JavaScript in your browser to complete this form.Please enable JavaScript in your browser to complete this form.Customer detailRef. No. *Customer Name *Attention to *Email *Tel No. *ProductSelect Product *T5500 Pressure GaugeB-Series Switches – Pressure, Differential Pressure & HydraulicT5500 Pressure GaugeVolume123ProductDial Size *100 - 100 mm160 - 160 mmModel *T5500 - Open front stainless steel pressure gaugeT6500 - Solid front stainless steel pressure gaugeWetted Parts Material *S - Stainless steel 316L (1.4404) tube and socketP - Monel tube and socketCase Filling *D - Dry caseL - Liquid fillied caseProcess Connection *02 - 1⁄4” NPT male03 - 3/8” NPT male04 - 1⁄2’’ NPT male09 - 9/16-18 UNF-2B Aminco13 - G 1⁄4 B male14 - G 3/8 B male15 - G 1⁄2 male16 - M20x1,5 male25 - 1⁄4’’ NPT femaleEJ - 7/16-20 UNF-3A 37° FlareKJ - PF 1⁄4 B parallel pipe male (JIS B 0202)KN - PF 1⁄2 B parallel pipe male (JIS B 0202)KP - PF 3/8 B parallel pipe male (JIS B 0202)KQ - R 1⁄2 DIN EN 10226-1 (1⁄2’’ BSPT / JIS B 0203)KR - R 3/8” DIN EN 10226-1 (3/8”’’ BSPT / JIS B 0203)RF - 9/16-18 UNF for 3⁄8” O.D. tubingConnection Location *B - Back (not available for model T6500)L - LowerRANGE *Engineering Unit *Additional OptionsAccuracyAJ - Special accuracy 0,5 % grade 2A according to ASME B40.100 (Not for ranges < 1 bar (dry) or < 4 bar (liquid filled))Agency ApprovalATEX - ATEX approval (see page 1) (only available with laminated safety glass)EAC - Custom declaration according Eurasian Conformity (Not in combination with option ATEX)Case MaterialYW - Case and ring material stainless steel 316LCase And RingBQ - Wall mounting bracketFF - Front flange on bayonet ring (Not for dial size 160 mm)FW - Wall mounting flangeFX - Front flange tack welded to caseUF - U-clamp for panel mounting (Not for model T6500)ConnectionTU - Throttle plugWP - No throttle plug in dry or liquid filled casesLiquid FillingGQ - White oilGR - Glycerine 99,5%GV - SiliconeGX - HalocarbonQC - Low temperature silicone for ambient temperature up to -70°C, includes Flourosilicone sealing (For 100 mm T6500 only)LJ - Field fillableDial OptoinsAB - Absolute pressureCS - Combination range / Dual scaleDN - Dial calibrated at angle other than vertical (Information is required by the customer)E6 - Dial pin in 6 o ́clock positionON - Without Ashcroft logo, neutralPR - Receiver gauge (Information is required by the customer)SS - Special Scale (Information is required by the customer)6Y - Skydrol useMovementLL - PLUS!TM Performance (Not available with Halocarbon filling)NZ - PLUS!TM Performance silicone free (Not for execution L (liquid filled))OS - Overload range stopVS - Underload range stop up to -1 barSM - Stainless steel 316L (1.4404) movementPointerMP - Adjustable micrometer pointerWindow *PD - Polycarbonate windowSG - Laminated safety glass (Standard with model T6500)EP - Maximum pointer and polycarbonate windowEQ - Minimum Pointer and polycarbonate windowSH - Red set hand stationary and polycarbonate windowAssemblyMO - Instrument assembled to accessoryMO1 - Instrument assembled to diaphragm sealCleaning6B - Cleaned for gaseous Oxygen or other strong oxidizing agents (Not for T5500 (open front) acc. to EN 837-1 and information is required by the customer)6W - Cleaned “free of oil and grease” (no Oxygen service)MF - Free from Mercury contaminationYF - Cleaned silicone free productMarking And TaggingDA - Dial marking printed on dial (Information is required by the customer)NH - Stainless steel tagging wired (Information is required by the customer)NH1 - Extra lage stainless steel tagging, wired (120 x 30 x 1 mm) (Information is required by the customer)Material CertificateCD2 - Certificate according to EN 10204 2.2C3 - Certificate according to EN 10204 3.1CD5 - Certificate according to NACE for Oilfields MR0175 / ISO 15156-2015 and for Refineries MR0103 / ISO 17945-2015MQ - Positive material certificate (PMI)Test CertificateC4 - CD-4 calibration certificateC43 - CD-4 calibration certificateCD10 - Calibration certificate 10 pointsHY - Hydrostatic pressure testML - Mass spectrometer leak testFile Upload Click or drag a file to this area to upload. Quantity *T5500 Pressure Gauge #2Product #2 *Dial Size #2 *100 - 100 mm160 - 160 mmModel #2 *T5500 - Open front stainless steel pressure gaugeT6500 - Solid front stainless steel pressure gaugeWetted Parts Material #2 *S - Stainless steel 316L (1.4404) tube and socketP - Monel tube and socketCase Filling #2 *D - Dry caseL - Liquid fillied caseProcess Connection #2 *02 - 1⁄4” NPT male03 - 3/8” NPT male04 - 1⁄2’’ NPT male09 - 9/16-18 UNF-2B Aminco13 - G 1⁄4 B male14 - G 3/8 B male15 - G 1⁄2 male16 - M20x1,5 male25 - 1⁄4’’ NPT femaleEJ - 7/16-20 UNF-3A 37° FlareKJ - PF 1⁄4 B parallel pipe male (JIS B 0202)KN - PF 1⁄2 B parallel pipe male (JIS B 0202)KP - PF 3/8 B parallel pipe male (JIS B 0202)KQ - R 1⁄2 DIN EN 10226-1 (1⁄2’’ BSPT / JIS B 0203)KR - R 3/8” DIN EN 10226-1 (3/8”’’ BSPT / JIS B 0203)RF - 9/16-18 UNF for 3⁄8” O.D. tubingConnection Location #2 *B - Back (not available for model T6500)L - LowerRANGE #2 *Engineering Unit #2 *Additional OptionsAccuracy #2AJ - Special accuracy 0,5 % grade 2A according to ASME B40.100 (Not for ranges < 1 bar (dry) or < 4 bar (liquid filled))Agency Approval #2ATEX - ATEX approval (see page 1) (only available with laminated safety glass)EAC - Custom declaration according Eurasian Conformity (Not in combination with option ATEX)Case Material #2YW - Case and ring material stainless steel 316LCase And Ring #2BQ - Wall mounting bracketFF - Front flange on bayonet ring (Not for dial size 160 mm)FW - Wall mounting flangeFX - Front flange tack welded to caseUF - U-clamp for panel mounting (Not for model T6500)Connection #2TU - Throttle plugWP - No throttle plug in dry or liquid filled casesLiquid Filling #2GQ - White oilGR - Glycerine 99,5%GV - SiliconeGX - HalocarbonQC - Low temperature silicone for ambient temperature up to -70°C, includes Flourosilicone sealing (For 100 mm T6500 only)LJ - Field fillableDial Optoins #2AB - Absolute pressureCS - Combination range / Dual scaleDN - Dial calibrated at angle other than vertical (Information is required by the customer)E6 - Dial pin in 6 o ́clock positionON - Without Ashcroft logo, neutralPR - Receiver gauge (Information is required by the customer)SS - Special Scale (Information is required by the customer)6Y - Skydrol useMovement #2LL - PLUS!TM Performance (Not available with Halocarbon filling)NZ - PLUS!TM Performance silicone free (Not for execution L (liquid filled))OS - Overload range stopVS - Underload range stop up to -1 barSM - Stainless steel 316L (1.4404) movementPointer #2MP - Adjustable micrometer pointerWindow #2 *PD - Polycarbonate windowSG - Laminated safety glass (Standard with model T6500)EP - Maximum pointer and polycarbonate windowEQ - Minimum Pointer and polycarbonate windowSH - Red set hand stationary and polycarbonate windowAssembly #2MO - Instrument assembled to accessoryMO1 - Instrument assembled to diaphragm sealCleaning #26B - Cleaned for gaseous Oxygen or other strong oxidizing agents (Not for T5500 (open front) acc. to EN 837-1 and information is required by the customer)6W - Cleaned “free of oil and grease” (no Oxygen service)MF - Free from Mercury contaminationYF - Cleaned silicone free productMarking And Tagging #2DA - Dial marking printed on dial (Information is required by the customer)NH - Stainless steel tagging wired (Information is required by the customer)NH1 - Extra lage stainless steel tagging, wired (120 x 30 x 1 mm) (Information is required by the customer)Material Certificate #2CD2 - Certificate according to EN 10204 2.2C3 - Certificate according to EN 10204 3.1CD5 - Certificate according to NACE for Oilfields MR0175 / ISO 15156-2015 and for Refineries MR0103 / ISO 17945-2015MQ - Positive material certificate (PMI)Test Certificate #2C4 - CD-4 calibration certificateC43 - CD-4 calibration certificateCD10 - Calibration certificate 10 pointsHY - Hydrostatic pressure testML - Mass spectrometer leak testFile Upload #2 Click or drag a file to this area to upload. Quantity #2 *T5500 Pressure Gauge #3Product #3 *Dial Size #3 *100 - 100 mm160 - 160 mmModel #3 *T5500 - Open front stainless steel pressure gaugeT6500 - Solid front stainless steel pressure gaugeWetted Parts Material #3 *S - Stainless steel 316L (1.4404) tube and socketP - Monel tube and socketCase Filling #3 *D - Dry caseL - Liquid fillied caseTest Certificate #3C4 - CD-4 calibration certificateC43 - CD-4 calibration certificateCD10 - Calibration certificate 10 pointsHY - Hydrostatic pressure testML - Mass spectrometer leak testFile Upload #3 Click or drag a file to this area to upload. Quantity #3 *B-Series Switches – Pressure, Differential Pressure & HydraulicVolume123ProductEnclosure *B4 - Pressure switch, Type 400, watertight enclosure meets NEMA 3, 4, 4X, 13 and IP66 requirements.B7 - Pressure switch, Type 700, explosion-proof enclosure meets Div. 1 & 2, NEMA 7, 9 and IP66 requirements. Standard housing epoxy coated aluminum. Use variation code XYW for 316SS housing.D4 - Differential pressure switch, Type 400, water-tight enclosure meets NEMA 3, 4, 4X, 13 and IP66 requirements.D7 - Differential pressure switch, Type 700, explosion- proof enclosure meets Div. 1 & 2, NEMA 7, 9 and IP66 requirements. Standard housing epoxy coated aluminum. Use variation code XYW for 316SS housing.Switch Element Selection - UL/CSA Listed SPDT20 - Narrow deadband ac, 15A - 125/250 Vac. Estimated dc rating, 0.4A, 120 Vdc (not UL listed).21 - Ammonia service, 5A - 125/250 Vac22 - Hermetically sealed switch, narrow deadband, 5A - 125/250 Vac. Estimated dc. rating, 2.5A, 28 Vdc (not UL listed).23 - Heavy duty ac, 22A - 125/250 Vac24 - General purpose, 15A - 125/250/480 Vac, 1⁄2A - 125 Vdc, 1⁄4A - 250 Vdc; 6A, 30 Vdc. (Standard switch)25 - Heavy duty dc, 10A - 125 Vac or dc,1⁄8 HP - 125 Vac or dc. Not available with psid ranges.26 - Sealed environment proof, 15A - 125/250 Vac. Estimated dc rating, 0.4A, 120 Vdc (not UL listed).27 - High temperature 300 °F, 15A - 125/250 Vac28 - Manual reset trip on, increasing 15A - 125/250 Vac. Not available with type 700 enclosure.29 - Manual reset trip on decreasing, 15A - 125/250 Vac. Not available with type 700 enclosure.31 - Low level (gold) contacts, 1A - 125 Vac32 - Hermetically sealed switch, general purpose, 11A - 125/250 Vac, 5A - 30 Vdc42 - Hermetically sealed switch, gold contacts, 1A - 125 Vac50 - Variable deadband, 15A - 125/250 VacSwitch Element Selection - UL/CSA Listed Dual (2 SPDT)61 - Dual narrow deadband, 15A - 125/250 Vac. Estimated dc rating, 0.4A, 120 Vdc (not UL listed).62 - Dual sealed environment proof, 15A - 125/250 Vac. Estimated dc rating, 0.4A, 120 Vdc (not UL listed).63 - Dual high temp. 300 °F, 15A - 125/250 Vac64 - Dual general purpose, 15A - 125/250/480 Vac, 1⁄2A- 125 Vdc, 1⁄4A - 250 Vdc65 - Dual ammonia service, 5A - 125/250 Vac67 - Dual hermetically sealed switch, narrow deadband, 5A - 125/250 Vac. Wires cannot be terminated inside B400 switch enclosure. Estimated dc. rating, 2.5A, 28 Vdc (not UL listed).68 - Dual hermetically sealed switch, general purpose, 11A - 125/250 Vac 5A, 30 Vdc. Wires cannot be terminated inside B400 switch enclosure.70 - Dual low level gold contacts, 1A - 125 Vac71 - Dual hermetically sealed switch, gold contacts, 1A - 125 Vac. Wires cannot be terminated inside B400 switch enclosure.Actuator Seal & Process Temp.B - Buna-N / 0 to 150V - VitonTM / 20 to 300T - TeflonTM / 0 to 150S - 316L / 0 to 300P - Monel® / 0 to 300OPTIONAL FEATURES AND ACCESSORIESXBP - Wall Mounting Bracket in. H2OXCH - Chained CoverXC8 - CSA ApprovalXCN - ATEX Directive 94/9/EC/IECEx RatingXC4 - Traceable Calibration CertificateXD2 - Dual Seal Rating (700 Series only)XFM - FM Approval – Single Element FM Approval – Dual ElementXFP - Fungus ProofingXFS - Factory Adjusted SetpointXG3 - Belleville ActuatorXG5 - UL Limit Control to 150 in. H2OXG6 - UL Limit Control to 600 psiXG7 - Secondary Chamber with VentXG8 - Steam Limit Control to 300 psiXG9 - Fire Safe Welded ActuatorXHS - High Static Differential PressureXHX - 160 psi (proof) d/p only 100 psi (proof) pressure only (in. H2O)XJK - Left Conduit ConnectionXJL - 3⁄4 ̋ to 1⁄2 ̋ Reducing BushingXJM - Metric Electrical Conduit Conn. M20 x 1.5XK3 - Terminal Block (700 Series only)XLE - 6 foot Leads on the Micro SwitchXNH - Tagging Stainless SteelXNN - Paper TagXPK - Pilot Light(s) Top MountedXPM - 3⁄4 ̋ Sealed Conduit Connection w/16 ̋ Lead WiresXTA - 316 Stainless Steel Pressure Connection for in. H2O RangeXTM - 2 ̋ Pipe Mounting BracketXUD - 316 Stainless Steel Pressure Conn.X06 - Pressure Connection: 1⁄2 NPT Male, 1⁄4 NPT Female 316 Stainless Steel (Combination)X07 - 1⁄2 NPTF Press. Conn., 316 SSX6B - Cleaned for Oxygen ServiceX9F - Inches of Water Housing for Outdoor UseXYW - 316SS HousingXMD - Metric Range on LabelXRN - Range ScaleRANGE *File Upload Click or drag a file to this area to upload. Quantity *B-Series Switches – Pressure, Differential Pressure & Hydraulic #2Product #2Enclosure #2 *B4 - Pressure switch, Type 400, watertight enclosure meets NEMA 3, 4, 4X, 13 and IP66 requirements.B7 - Pressure switch, Type 700, explosion-proof enclosure meets Div. 1 & 2, NEMA 7, 9 and IP66 requirements. Standard housing epoxy coated aluminum. Use variation code XYW for 316SS housing.D4 - Differential pressure switch, Type 400, water-tight enclosure meets NEMA 3, 4, 4X, 13 and IP66 requirements.D7 - Differential pressure switch, Type 700, explosion- proof enclosure meets Div. 1 & 2, NEMA 7, 9 and IP66 requirements. Standard housing epoxy coated aluminum. Use variation code XYW for 316SS housing.Switch Element Selection - UL/CSA Listed SPDT #220 - Narrow deadband ac, 15A - 125/250 Vac. Estimated dc rating, 0.4A, 120 Vdc (not UL listed).21 - Ammonia service, 5A - 125/250 Vac22 - Hermetically sealed switch, narrow deadband, 5A - 125/250 Vac. Estimated dc. rating, 2.5A, 28 Vdc (not UL listed).23 - Heavy duty ac, 22A - 125/250 Vac24 - General purpose, 15A - 125/250/480 Vac, 1⁄2A - 125 Vdc, 1⁄4A - 250 Vdc; 6A, 30 Vdc. (Standard switch)25 - Heavy duty dc, 10A - 125 Vac or dc,1⁄8 HP - 125 Vac or dc. Not available with psid ranges.26 - Sealed environment proof, 15A - 125/250 Vac. Estimated dc rating, 0.4A, 120 Vdc (not UL listed).27 - High temperature 300 °F, 15A - 125/250 Vac28 - Manual reset trip on, increasing 15A - 125/250 Vac. Not available with type 700 enclosure.29 - Manual reset trip on decreasing, 15A - 125/250 Vac. Not available with type 700 enclosure.31 - Low level (gold) contacts, 1A - 125 Vac32 - Hermetically sealed switch, general purpose, 11A - 125/250 Vac, 5A - 30 Vdc42 - Hermetically sealed switch, gold contacts, 1A - 125 Vac50 - Variable deadband, 15A - 125/250 VacSwitch Element Selection - UL/CSA Listed Dual (2 SPDT) #261 - Dual narrow deadband, 15A - 125/250 Vac. Estimated dc rating, 0.4A, 120 Vdc (not UL listed).62 - Dual sealed environment proof, 15A - 125/250 Vac. Estimated dc rating, 0.4A, 120 Vdc (not UL listed).63 - Dual high temp. 300 °F, 15A - 125/250 Vac64 - Dual general purpose, 15A - 125/250/480 Vac, 1⁄2A- 125 Vdc, 1⁄4A - 250 Vdc65 - Dual ammonia service, 5A - 125/250 Vac67 - Dual hermetically sealed switch, narrow deadband, 5A - 125/250 Vac. Wires cannot be terminated inside B400 switch enclosure. Estimated dc. rating, 2.5A, 28 Vdc (not UL listed).68 - Dual hermetically sealed switch, general purpose, 11A - 125/250 Vac 5A, 30 Vdc. Wires cannot be terminated inside B400 switch enclosure.70 - Dual low level gold contacts, 1A - 125 Vac71 - Dual hermetically sealed switch, gold contacts, 1A - 125 Vac. Wires cannot be terminated inside B400 switch enclosure.Actuator Seal & Process Temp. #2B - Buna-N / 0 to 150V - VitonTM / 20 to 300T - TeflonTM / 0 to 150S - 316L / 0 to 300P - Monel® / 0 to 300OPTIONAL FEATURES AND ACCESSORIES #2XBP - Wall Mounting Bracket in. H2OXCH - Chained CoverXC8 - CSA ApprovalXCN - ATEX Directive 94/9/EC/IECEx RatingXC4 - Traceable Calibration CertificateXD2 - Dual Seal Rating (700 Series only)XFM - FM Approval – Single Element FM Approval – Dual ElementXFP - Fungus ProofingXFS - Factory Adjusted SetpointXG3 - Belleville ActuatorXG5 - UL Limit Control to 150 in. H2OXG6 - UL Limit Control to 600 psiXG7 - Secondary Chamber with VentXG8 - Steam Limit Control to 300 psiXG9 - Fire Safe Welded ActuatorXHS - High Static Differential PressureXHX - 160 psi (proof) d/p only 100 psi (proof) pressure only (in. H2O)XJK - Left Conduit ConnectionXJL - 3⁄4 ̋ to 1⁄2 ̋ Reducing BushingXJM - Metric Electrical Conduit Conn. M20 x 1.5XK3 - Terminal Block (700 Series only)XLE - 6 foot Leads on the Micro SwitchXNH - Tagging Stainless SteelXNN - Paper TagXPK - Pilot Light(s) Top MountedXPM - 3⁄4 ̋ Sealed Conduit Connection w/16 ̋ Lead WiresXTA - 316 Stainless Steel Pressure Connection for in. H2O RangeXTM - 2 ̋ Pipe Mounting BracketXUD - 316 Stainless Steel Pressure Conn.X06 - Pressure Connection: 1⁄2 NPT Male, 1⁄4 NPT Female 316 Stainless Steel (Combination)X07 - 1⁄2 NPTF Press. Conn., 316 SSX6B - Cleaned for Oxygen ServiceX9F - Inches of Water Housing for Outdoor UseXYW - 316SS HousingXMD - Metric Range on LabelXRN - Range ScaleRANGE #2 *File Upload #2 Click or drag a file to this area to upload. Quantity #2 *B-Series Switches – Pressure, Differential Pressure & Hydraulic #3Product #3Enclosure #3 *B4 - Pressure switch, Type 400, watertight enclosure meets NEMA 3, 4, 4X, 13 and IP66 requirements.B7 - Pressure switch, Type 700, explosion-proof enclosure meets Div. 1 & 2, NEMA 7, 9 and IP66 requirements. Standard housing epoxy coated aluminum. Use variation code XYW for 316SS housing.D4 - Differential pressure switch, Type 400, water-tight enclosure meets NEMA 3, 4, 4X, 13 and IP66 requirements.D7 - Differential pressure switch, Type 700, explosion- proof enclosure meets Div. 1 & 2, NEMA 7, 9 and IP66 requirements. Standard housing epoxy coated aluminum. Use variation code XYW for 316SS housing.Switch Element Selection - UL/CSA Listed SPDT #320 - Narrow deadband ac, 15A - 125/250 Vac. Estimated dc rating, 0.4A, 120 Vdc (not UL listed).21 - Ammonia service, 5A - 125/250 Vac22 - Hermetically sealed switch, narrow deadband, 5A - 125/250 Vac. Estimated dc. rating, 2.5A, 28 Vdc (not UL listed).23 - Heavy duty ac, 22A - 125/250 Vac24 - General purpose, 15A - 125/250/480 Vac, 1⁄2A - 125 Vdc, 1⁄4A - 250 Vdc; 6A, 30 Vdc. (Standard switch)25 - Heavy duty dc, 10A - 125 Vac or dc,1⁄8 HP - 125 Vac or dc. Not available with psid ranges.26 - Sealed environment proof, 15A - 125/250 Vac. Estimated dc rating, 0.4A, 120 Vdc (not UL listed).27 - High temperature 300 °F, 15A - 125/250 Vac28 - Manual reset trip on, increasing 15A - 125/250 Vac. Not available with type 700 enclosure.29 - Manual reset trip on decreasing, 15A - 125/250 Vac. Not available with type 700 enclosure.31 - Low level (gold) contacts, 1A - 125 Vac32 - Hermetically sealed switch, general purpose, 11A - 125/250 Vac, 5A - 30 Vdc42 - Hermetically sealed switch, gold contacts, 1A - 125 Vac50 - Variable deadband, 15A - 125/250 VacSwitch Element Selection - UL/CSA Listed Dual (2 SPDT) #361 - Dual narrow deadband, 15A - 125/250 Vac. Estimated dc rating, 0.4A, 120 Vdc (not UL listed).62 - Dual sealed environment proof, 15A - 125/250 Vac. Estimated dc rating, 0.4A, 120 Vdc (not UL listed).63 - Dual high temp. 300 °F, 15A - 125/250 Vac64 - Dual general purpose, 15A - 125/250/480 Vac, 1⁄2A- 125 Vdc, 1⁄4A - 250 Vdc65 - Dual ammonia service, 5A - 125/250 Vac67 - Dual hermetically sealed switch, narrow deadband, 5A - 125/250 Vac. Wires cannot be terminated inside B400 switch enclosure. Estimated dc. rating, 2.5A, 28 Vdc (not UL listed).68 - Dual hermetically sealed switch, general purpose, 11A - 125/250 Vac 5A, 30 Vdc. Wires cannot be terminated inside B400 switch enclosure.70 - Dual low level gold contacts, 1A - 125 Vac71 - Dual hermetically sealed switch, gold contacts, 1A - 125 Vac. Wires cannot be terminated inside B400 switch enclosure.Actuator Seal & Process Temp. #3B - Buna-N / 0 to 150V - VitonTM / 20 to 300T - TeflonTM / 0 to 150S - 316L / 0 to 300P - Monel® / 0 to 300OPTIONAL FEATURES AND ACCESSORIES #3XBP - Wall Mounting Bracket in. H2OXCH - Chained CoverXC8 - CSA ApprovalXCN - ATEX Directive 94/9/EC/IECEx RatingXC4 - Traceable Calibration CertificateXD2 - Dual Seal Rating (700 Series only)XFM - FM Approval – Single Element FM Approval – Dual ElementXFP - Fungus ProofingXFS - Factory Adjusted SetpointXG3 - Belleville ActuatorXG5 - UL Limit Control to 150 in. H2OXG6 - UL Limit Control to 600 psiXG7 - Secondary Chamber with VentXG8 - Steam Limit Control to 300 psiXG9 - Fire Safe Welded ActuatorXHS - High Static Differential PressureXHX - 160 psi (proof) d/p only 100 psi (proof) pressure only (in. H2O)XJK - Left Conduit ConnectionXJL - 3⁄4 ̋ to 1⁄2 ̋ Reducing BushingXJM - Metric Electrical Conduit Conn. M20 x 1.5XK3 - Terminal Block (700 Series only)XLE - 6 foot Leads on the Micro SwitchXNH - Tagging Stainless SteelXNN - Paper TagXPK - Pilot Light(s) Top MountedXPM - 3⁄4 ̋ Sealed Conduit Connection w/16 ̋ Lead WiresXTA - 316 Stainless Steel Pressure Connection for in. H2O RangeXTM - 2 ̋ Pipe Mounting BracketXUD - 316 Stainless Steel Pressure Conn.X06 - Pressure Connection: 1⁄2 NPT Male, 1⁄4 NPT Female 316 Stainless Steel (Combination)X07 - 1⁄2 NPTF Press. Conn., 316 SSX6B - Cleaned for Oxygen ServiceX9F - Inches of Water Housing for Outdoor UseXYW - 316SS HousingXMD - Metric Range on LabelXRN - Range ScaleRANGE #3 *File Upload #3 Click or drag a file to this area to upload. Quantity #3 *Sales detailQT Date *Sales Name *ปริญญา บัณฑิตธรรมรวินท์รัชต์ เจียมใจงามโฆษิต โชติวิวัฒน์กิจมัลลิกา โรจน์คงทรัพย์มรกต คูสกุลนิรดา สุขหวานกีรติญา เนตรไธสงค์กนกกาญจน์ ธเนศชัยคุปต์NoteStatusNew OrderIn processFinishCancelSubmit